Bruker Autoflex maX TOF-TOF MALDI Mass Spectrometer

Mass SpectrometryBy rakeshs

Bruker Autoflex maX TOF/TOF MALDI Mass Spectrometer Mass Range : up to 500,000 Resolution : Linear Mode Positive Ion Mode            ≥ 1,100 @ m/z 12,361 (Cytochrome C) Negative Ion Mode          ≥ 2,500 @ m/z 1,569 (Glu-Fib) Reflector Mode Positive Ion Mode           >…

Read more

Bruker Microflex MALDI-TOF Mass Spectrometer

Mass SpectrometryBy rakeshs

Bruker Microflex MALDI-TOF Mass Spectrometer Mass Range : up to 300,000 Resolution : 15,000 Mass accuracy: 15 (int. calib.) [ppm] Laser: Nitrogen (337nm) Laser frequency [Hz]: 60 (MS) Bruker Microflex MALDI-TOF-MS Location: Hunter 240 Contact:  Dr. Rakesh Sachdeva

Read more

Shimadzu QP2010 Plus with AOC 20i+s autosampler

Mass Spectrometry, Gas ChromatographyBy rakeshs

Shimadzu QP2010 Plus with AOC 20i+s autosampler Injector: Split / Splitless Detector: MS, FID Column: SH-Rxi-Sil5MS, 30m x 0.25mm x 0.25 μm SH-Rxi-5MS, 15m x 0.25mm x 0.25 μm Mass range: m/z to 1,000 El scan S/N: 1pg octa fluoronapthalene m/z 272 S/N ≥ 600 (helium gas) High-speed scan rate: 10,000 u/sec Shimadzu QP2010 GCMS…

Read more

Agilent 6545 QTOF LC-MS/MS Mass Spectrometer

Mass Spectrometry, Molecular StructureBy rakeshs

Agilent 6545 QTOF LC-MS/MS Mass Spectrometer Mass range – 50-10,000 m/z Dynamic range : 5 orders of magnitude Resolving power : 45,000 FWHM at m/z 2722 RMS :   0.8 ppm at (M+H)+ ion m/z 609.2807 (reserpine) in MS mode better than 2 ppm RMS on m/z 397 of reserpine in MS/MS mode. Spectral acquisition…

Read more

Policy/Terms of Use

  • Web Accessibility
  • Ethics/Safety Hotline
  • Privacy Policy
Copyright © 2021

Clemson University Clemson, South Carolina 29634

clemson u logo

Find us on:

Facebook page opens in new windowTwitter page opens in new windowYouTube page opens in new windowLinkedin page opens in new windowInstagram page opens in new window

Architectural drawings © 2020 James Barker. All rights reserved.

Policy/Terms of Use

  • A-Z Index
  • Campus Map
  • CU Safety
  • Directory
  • Webcams
  • Apply to Clemson
Go to Top