Agilent Cary 60 UV-Vis Spectrophotometer

Agilent Cary 60 UV-Vis Spectrophotometer Optical Specifications Wavelength range190–1100 nm Xenon pulse lamp source Slit width1.5 nm Wavelength accuracy <±0.06 nm at 541.94 nm Wavelength reproducibility<±0.01 Photometric accuracy<±0.0007 Abs at 1 Abs (NIST 930e) Peltier cooled liquid sample holder Solid / Film sample holder Agilent Cary 60 UV-Vis Spectrophotometer Location: Hunter 247B Contact: Dr. Rakesh…

Beckmann Coulter  DTX880  Photomultiplier Detector Multimode Plate Reader

Beckmann Coulter  DTX880  Photomultiplier Detector Multimode Plate Reader Fluorescence Intensity-Top Read Wavelength Range: Detection Limit (96-Well): Detection Limit(384-Well): Linear Dynamic Range: Read Time (Fly Mode):   Absorbance Wavelength Range: Indication Range: Accuracy: Reproducibility: Read Time: aaa 230-750 nm 1.5 fmol/100 µL fluorescein 1.5 fmol/100 µL fluorescein 5 decades 18 sec on 96-well; 37 sec on…

Horiba iHR-320 Raman Spectrometer

Horiba iHR-320 Raman Spectrometer Aperture f/4.1 Spectral Range 150 to 1500 nm with 1200 g/mm grating 150 nm to 40 µm with appropriate gratings Grating Size 68 mm x 68 mm Number of Gratings on Turret 3 Flat Field Size 30 mm x 12 mm Resolution with Exit Slit and PMT 0.06 nm Wavelength Accuracy…

Rigaku SmartLab Powder X-ray Diffractometer

Rigaku SmartLab Powder X-ray Diffractometer Cu sealed tube X-ray source. 10-position rotating sample changer. Theta-Theta goniometer. Zero background sample holders. HyPix-3000 2D HPAD detector. HT 1500 high temperature attachment for in-situ measurements. SmartLab Studio II software suite for instrument control, data processing, phase identification, Rietveld refinement. Access to the ICDD database. Location: Hunter 338 Contact:…

Bruker D8 Quest Single Crystal X-ray diffractometer

Bruker D8 Quest Single Crystal X-ray diffractometer Mo sealed tube X-ray source. TRIUMPH monochromator. Fixed chi goniometer. Photon 100 CMOS detector. Oxford Cryostream 800 for data collections at 90-400 K. Apex 3 software suite for instrument control, data processing, structure refinement (SHELXTL). Access to the Cambridge Structural Database and the Inorganic Crystal Structure Database. Location:…

Bruker D8 Venture Duo Single Crystal X-ray diffractometer

Bruker D8 Venture Duo Single Crystal X-ray diffractometer Mo and Cu microfocus X-ray sources. Kappa goniometer. Photon 2 CMOS detector. Oxford Cryostream 700 for data collections at 90-400 K. Apex 3 software suite for instrument control, data processing, structure refinement (SHELXTL). Access to the Cambridge Structural Database and the Inorganic Crystal Structure Database. Location: Hunter…

Thermo Nicolet Nexus 670 FTIR Spectrometer

Spectral range: 7800–350 cm-1 optimized, mid-infrared KBr beamsplitter KBr optics: 4 cm-1 spectral resolution Signal-to-noise: Guaranteed: 5 seconds: 8000:1 (peak to peak), 1 minute: 22,000:1 (peak to peak), Typical: 1 minute: 28,000:1 (peak to peak) Spectral resolution: better than 0.8 cm-1; better than 0.5 cm-1 using aperture Wavelength precision: 0.01 cm-1 at 2000 cm-1 Detector:…