Molecular Structure

Bruker Autoflex maX TOF-TOF MALDI Mass Spectrometer

Bruker Autoflex maX TOF/TOF MALDI Mass Spectrometer Mass Range : up to 500,000 Resolution : Linear Mode Positive Ion Mode            ≥ 1,100 @ m/z 12,361 (Cytochrome C) Negative Ion Mode          ≥ 2,500 @ m/z 1,569 (Glu-Fib) Reflector Mode Positive Ion Mode           >…

Read more

Agilent Cary 60 UV-Vis Spectrophotometer

Agilent Cary 60 UV-Vis Spectrophotometer Optical Specifications Wavelength range190–1100 nm Xenon pulse lamp source Slit width1.5 nm Wavelength accuracy <±0.06 nm at 541.94 nm Wavelength reproducibility<±0.01 Photometric accuracy<±0.0007 Abs at 1 Abs (NIST 930e) Peltier cooled liquid sample holder Solid / Film sample holder Agilent Cary 60 UV-Vis Spectrophotometer Location: Hunter 247B Contact: Dr. Rakesh…

Read more

Beckmann Coulter  DTX880  Photomultiplier Detector Multimode Plate Reader

Beckmann Coulter  DTX880  Photomultiplier Detector Multimode Plate Reader Fluorescence Intensity-Top Read Wavelength Range: Detection Limit (96-Well): Detection Limit(384-Well): Linear Dynamic Range: Read Time (Fly Mode):   Absorbance Wavelength Range: Indication Range: Accuracy: Reproducibility: Read Time: aaa 230-750 nm 1.5 fmol/100 µL fluorescein 1.5 fmol/100 µL fluorescein 5 decades 18 sec on 96-well; 37 sec on…

Read more

Horiba iHR-320 Raman Spectrometer

Horiba iHR-320 Raman Spectrometer Aperture f/4.1 Spectral Range 150 to 1500 nm with 1200 g/mm grating 150 nm to 40 µm with appropriate gratings Grating Size 68 mm x 68 mm Number of Gratings on Turret 3 Flat Field Size 30 mm x 12 mm Resolution with Exit Slit and PMT 0.06 nm Wavelength Accuracy…

Read more

Bruker Microflex MALDI-TOF Mass Spectrometer

Bruker Microflex MALDI-TOF Mass Spectrometer Mass Range : up to 300,000 Resolution : 15,000 Mass accuracy: 15 (int. calib.) [ppm] Laser: Nitrogen (337nm) Laser frequency [Hz]: 60 (MS) Bruker Microflex MALDI-TOF-MS Location: Hunter 240 Contact:  Dr. Rakesh Sachdeva

Read more

Rigaku SmartLab Powder X-ray Diffractometer

Rigaku SmartLab Powder X-ray Diffractometer Cu sealed tube X-ray source. 10-position rotating sample changer. Theta-Theta goniometer. Zero background sample holders. HyPix-3000 2D HPAD detector. HT 1500 high temperature attachment for in-situ measurements. SmartLab Studio II software suite for instrument control, data processing, phase identification, Rietveld refinement. Access to the ICDD database. Location: Hunter 338 Contact:…

Read more

Rigaku Ultima IV Powder X-ray Diffractometer

Rigaku Ultima IV Powder X-ray Diffractometer Cu sealed tube X-ray source. 10-position rotating sample changer. Theta-Theta goniometer. Zero background sample holders. Scintillation counter detector with monochromator. PDXL software suite for instrument control, data processing, phase identification. Access to the ICDD database. Location: Hunter 338 Contact: Dr. Colin McMillen

Read more

Bruker D8 Quest Single Crystal X-ray diffractometer

Bruker D8 Quest Single Crystal X-ray diffractometer Mo sealed tube X-ray source. TRIUMPH monochromator. Fixed chi goniometer. Photon 100 CMOS detector. Oxford Cryostream 800 for data collections at 90-400 K. Apex 3 software suite for instrument control, data processing, structure refinement (SHELXTL). Access to the Cambridge Structural Database and the Inorganic Crystal Structure Database. Location:…

Read more

Bruker D8 Venture Duo Single Crystal X-ray diffractometer

Bruker D8 Venture Duo Single Crystal X-ray diffractometer Mo and Cu microfocus X-ray sources. Kappa goniometer. Photon 2 CMOS detector. Oxford Cryostream 700 for data collections at 90-400 K. Apex 3 software suite for instrument control, data processing, structure refinement (SHELXTL). Access to the Cambridge Structural Database and the Inorganic Crystal Structure Database. Location: Hunter…

Read more

Thermo Nicolet Nexus 670 FTIR Spectrometer

Spectral range: 7800–350 cm-1 optimized, mid-infrared KBr beamsplitter KBr optics: 4 cm-1 spectral resolution Signal-to-noise: Guaranteed: 5 seconds: 8000:1 (peak to peak), 1 minute: 22,000:1 (peak to peak), Typical: 1 minute: 28,000:1 (peak to peak) Spectral resolution: better than 0.8 cm-1; better than 0.5 cm-1 using aperture Wavelength precision: 0.01 cm-1 at 2000 cm-1 Detector:…

Read more

Nicolet iS5 FTIR Spectrometer

Spectral range: 7800–350 cm-1 optimized, mid-infrared KBr beamsplitter Signal-to noise: guaranteed: 5 seconds: 8000:1 (peak to peak), typical: 1 minute: 28,000:1 (peak to peak) Spectral resolution: better than 0.8 cm-1; better than 0.5 cm-1 using aperture Wavelength precision:0.01 cm-1 at 2000 cm-1 KBr optics: 4 cm-1 spectral resolution Detector: fast recovery deuterated triglycine sulfate (DTGS)…

Read more

Shimadzu IRAffinity-1S FTIR Spectrometer

Accessory : MIRacle 10 ATR, transmission Beam splitter : Germanium-coated KBr Light source : High-energy ceramic light source Detector : DLATGS detector equipped with temperature control mechanism Wavenumber range: 7,800 to 350 cm-1 Resolution : 0.5, 1, 2, 4, 8, 16 cm-1 Shimadzu IRAffinity-IS Location: Hunter 247B Contact: Dr. Rakesh Sachdeva

Read more

Bruker Avance Neo-500 Nuclear Magnetic Resonance Spectrometer

High Resolution Multinuclear two-channel NMR spectrometer equipped with 5 mm SmartProbe. The SmartProbe delivers high sensitivity on both the multinuclear and proton channels.  A further key feature that this probe offers is the ability to observe ¹⁹F with ¹H decoupling. The probe features full Auto Tune and Match (ATM) capability across its complete range of nuclei,…

Read more

Bruker Avance NEO-300 Nuclear Magnetic Resonance Spectrometer

A high-resolution multinuclear two-channel NMR spectrometer with a proton frequency of 300 MHz equipped with a BBFO 5 mm probe. Ideal instrument for fast routine 1D and 2D NMR experiments and multinuclear experiments. The installed BBFO Probe allows the measurement of a wide range of nuclei, including ¹H, ¹⁹F, and X-broadband (³¹P–¹⁵N). Its design allows…

Read more

Bruker Avance NEO-500 Nuclear Magnetic Resonance Spectrometer (CryoProbe)

A high-resolution, multinuclear, two-channel NMR spectrometer designed for advanced solution-state studies. Proton NMR frequency – 500 MHz. The system is equipped with a 5 mm Prodigy CryoProbe, featuring full Auto Tune and Match (ATM) capability across its complete range of nuclei, including ¹H, ¹⁹F, and X-broadband (³¹P–¹⁵N). The Prodigy CryoProbe offers a substantial improvement in…

Read more

Shimadzu QP2010 Plus with AOC 20i+s autosampler

Shimadzu QP2010 Plus with AOC 20i+s autosampler Injector: Split / Splitless Detector: MS, FID Column: SH-Rxi-Sil5MS, 30m x 0.25mm x 0.25 μm SH-Rxi-5MS, 15m x 0.25mm x 0.25 μm Mass range: m/z to 1,000 El scan S/N: 1pg octa fluoronapthalene m/z 272 S/N ≥ 600 (helium gas) High-speed scan rate: 10,000 u/sec Shimadzu QP2010 GCMS…

Read more

Bruker Avance NEO-500 Solid-State Nuclear Magnetic Resonance Spectrometer

A multinuclear, two-channel NMR spectrometer designed for high-resolution solid-state studies with Magic Angle Spinning (MAS) operates at a proton frequency of 500 MHz (B₀ = 11.75 T). The system is equipped with a 3.2 mm iProbe CPMAS optimized for fast MAS (up to 24 kHz) and high sensitivity in rigid solids, as well as a 4…

Read more

Agilent 6545 QTOF LC-MS/MS Mass Spectrometer

Agilent 6545 QTOF LC-MS/MS Mass Spectrometer Mass range – 50-10,000 m/z Dynamic range : 5 orders of magnitude Resolving power : 45,000 FWHM at m/z 2722 RMS :   0.8 ppm at (M+H)+ ion m/z 609.2807 (reserpine) in MS mode better than 2 ppm RMS on m/z 397 of reserpine in MS/MS mode. Spectral acquisition…

Read more

Nicolet Magna IR 550 FTIR Spectrometer

Measuring range: 350 – 7400 cm-1 Spectral resolution: 0.5 cm-1 Beamsplitters: KBr (350 – 7400 cm-1) Suited for experiments in step scan, linear scan, time resolved, and rapid scan spectroscopy TM Interferometer Rapid scanning interferometer. Continuous dynamic alignment of interferometer. 2 mirrors from beamsplitter to detector: single parabolic mirror from beamsplitter to sample: single ellipsoidal mirror…

Read more

Agilent 8453 UV-Vis Spectrophotometer

Optical Specifications Wavelength range190–1100 nm Slit width1 nm Wavelength accuracy <±0.5 nm(NIST 2034) Wavelength reproducibility<±0.02 nm ten consecutive scans (NIST 2034) Photometric accuracy<±0.005 A at 1 A (NIST 930e) Agilent 8453 UV-Vis Spectrophotometer Location: Hunter 319 Contact: Dr. Rakesh Sachdeva

Read more