{"id":3782,"date":"2021-09-13T18:54:12","date_gmt":"2021-09-13T22:54:12","guid":{"rendered":"https:\/\/scienceweb.clemson.edu\/aif\/?p=3782"},"modified":"2022-05-02T12:36:38","modified_gmt":"2022-05-02T16:36:38","slug":"mettler-dsc","status":"publish","type":"post","link":"https:\/\/scienceweb.clemson.edu\/aif\/mettler-dsc\/","title":{"rendered":"Mettler Toledo DSC 3+ STAR\u1d49 Differential Scanning Calorimeter"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text][\/vc_column_text][vc_column_text]Temperature range: -150 to 700 \u00b0C<\/p>\n<p>Sensor: FRS 6+ with 56 thermocouples or HSS 9+ with 120 thermocouples<\/p>\n<p>Heating rate: 0.02 to 300 K\/min<\/p>\n<p>TAWN resolution (FRS \/HSS): 0.12\/0.2<\/p>\n<p>TAWN sensitivity (FRS \/HSS): 11.9\/56<\/p>\n<p>Indium response ratio (FRS sensor): &gt;155\/85 mW\/\u00b0C<\/p>\n<p>Material number(s): 30139230<\/p>\n<p>Autosampler[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;3783&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221;][vc_btn title=&#8221;Mettler Toledo DSC 3+&#8221; align=&#8221;center&#8221; link=&#8221;url:https%3A%2F%2Fclemson.box.com%2Fs%2F52ivhe4yqpxopjjlj5kfwj44liit3lsk|title:Mettler%20Toledo%20DSC%203%2B|target:_blank&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]Location: Hunter 241A[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]<\/p>\n<p style=\"text-align: center\">Contact: <a href=\"https:\/\/scienceweb.clemson.edu\/aif\/dr-rakesh-sachdeva\/\">Dr. Rakesh Sachdeva<\/a><\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text][\/vc_column_text][vc_column_text]Temperature range: -150 to 700 \u00b0C Sensor: FRS 6+ with 56 thermocouples or HSS 9+ with 120 thermocouples Heating rate: 0.02 to 300 K\/min TAWN resolution (FRS \/HSS): 0.12\/0.2 TAWN sensitivity (FRS \/HSS): 11.9\/56 Indium response ratio (FRS sensor): &gt;155\/85 mW\/\u00b0C Material number(s): 30139230 Autosampler[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;3783&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221;][vc_btn title=&#8221;Mettler Toledo DSC 3+&#8221; align=&#8221;center&#8221;&hellip;<\/p>\n","protected":false},"author":24,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_links_to":"","_links_to_target":""},"categories":[77,85],"tags":[],"class_list":["post-3782","post","type-post","status-publish","format-standard","hentry","category-thermal-analysis","category-dsc","category-77","category-85","description-off"],"_links":{"self":[{"href":"https:\/\/scienceweb.clemson.edu\/aif\/wp-json\/wp\/v2\/posts\/3782","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/scienceweb.clemson.edu\/aif\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/scienceweb.clemson.edu\/aif\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/scienceweb.clemson.edu\/aif\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/scienceweb.clemson.edu\/aif\/wp-json\/wp\/v2\/comments?post=3782"}],"version-history":[{"count":0,"href":"https:\/\/scienceweb.clemson.edu\/aif\/wp-json\/wp\/v2\/posts\/3782\/revisions"}],"wp:attachment":[{"href":"https:\/\/scienceweb.clemson.edu\/aif\/wp-json\/wp\/v2\/media?parent=3782"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/scienceweb.clemson.edu\/aif\/wp-json\/wp\/v2\/categories?post=3782"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/scienceweb.clemson.edu\/aif\/wp-json\/wp\/v2\/tags?post=3782"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}